Water Base Mud
Home Up

 

Home MCT-1000 MCT-500 Oil Base Mud Water Base Mud Rate Sheet

Dennis Energy Services, Inc.

 

SITUATION

PRODUCTS

LBS/BBL

PILL VOLUME

SWEEP FREQUENCY

 

NOTES

 

PREVENTIVE SWEEPS  

 

 

 

MCT-1000

 

8 P.P.B.

 

15 – 25 bbls

 

6 – 8 hours

w         Pump sweep every 6 0 8 hours, and additional as each potential problem sand is drilled.

w         Drill 15’ of sand – Pump 15 bbl sweep.

w         Pump 15 bbl sweep at base of sand.

w         Continue sweeps as long as underblalaced sands are exposed.

w         Maintain pH above 9.5  

 

SEEPAGE SWEEPS

 

MCT-1000

 

10 P.P.B.

 

25 – 50 bbls

 

4 hours or 100’ of new hole drilled

w         Pump 25 – 50 bbls sweeps (calculated to cover 500’ of hole).

w         Pump sweep every 4 hours or 100’ of hole drilled.

w         Adjust frequency for severity of problems.

w         Continue sweeping program as long as underbalanced sands are exposed.

w         Maintain pH above 9.5.

 

 

LOST CIRCULATION

 

“PARTIAL RETURNS”

 

MCT- 500

   

MCT-1000

 

15 P.P.B.

 

 

15 P.P.B.

 

50 bbls

 

Pump sweeps as conditions dictate

w         Mix DESI SEAL Medium first, then add the fine.

w         Dilute with mud or water as required.

w         Pump sweeps at reduced speed.

w         Adjust concentration and frequency as conditions dictate.

w         Spot pill in place should conditions worsen.

 

 

LOST CIRCULATION

 

TOTAL LOSS & LESS THAN 50% RETURNS

 

8.8 – 11.0 PPB MUD  MCT-500 MCT-1000

 

11.1 – 14 PPG MUD MCT-500 MCT-1000

 

14.1-17 PPG MUD   MCT-1000

 

40 PPB MIX      28 PPB 12 PPB

30 PPB MIX      21 PPB 9 PPB

 

25 PPB MIX      17 PPB 10 PPB

 

50 bbls

 

Spot pills

 

Follow up with sweeping program as required.

w         Mix Medium first, then add the fine.

w         Dilute with mud or water as required.

w         Pump pill at reduced pump speed.

w         Spot pill at suspected loss zone.

w         POOH (or to last casing) Allow hole to heal.

w         Stage in hole after regaining circulation.

w         Establish regular sweeping program to TD.

w         Heavier mud weights will limit and dictate amounts of fiber that can be added in the pill.

w         Products recommendation are based on 70% Medium and 30% Fine mixtures